{"id":9327,"date":"2024-10-16T19:58:03","date_gmt":"2024-10-16T19:58:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-f1791\/"},"modified":"2024-10-24T11:11:15","modified_gmt":"2024-10-24T11:11:15","slug":"astm-f1791","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-f1791\/","title":{"rendered":"ASTM-F1791"},"content":{"rendered":"<\/p>\n
1.1 This specification covers the design, construction, test, and performance requirements for air or nitrogen system filters, referred to hereinafter as filters. These filters are intended to be installed in-line to protect equipment from particular contamination.<\/p>\n
1.2 The values stated in this specification in inch-pounds units are to be regarded as the standard. The SI equivalent shown in parentheses are provided for information only.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Classification TABLE 1 TABLE 2 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Ordering Information Filter Design and Construction TABLE 3 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Performance Tests Required Marking <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Quality Assurance System <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | X1. GUIDELINES FOR THE SELECTION AND INSTALLATION OF FILTERS X1.1 Scope X1.2 Contamination Removal Rating (also commonly termed: \u201cfilter rating\u201d\u009d or \u201cmicrometre rating\u201d\u009d) X1.3 Filter Element Bypass X1.4 Permanent Versus Disposal Elements <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | X1.5 Contaminant-Holding Capacity X1.6 Differential Pressure Indicator <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" F1791-00(2006) Standard Specification for Filters Used in Air or Nitrogen Systems<\/b><\/p>\n |