BS 1902-10.2:1994:2003 Edition
$102.76
Methods of testing refractory materials. Investment casting shell mould systems – Determination of permeability and standard air flow capacity at elevated temperatures – Section 10.2: Determination of permeability and standard air flow capacity at elevated temperatures
Published By | Publication Date | Number of Pages |
BSI | 2003 | 20 |
This Section of BS 1902-10 describes a method for determining the standard air flow capacity of investment casting shell moulds, and the inherent permeability of the shell material, at elevated temperatures.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | BRITISH STANDARD |
2 | Committees responsible for this British Standard |
3 | Contents |
5 | 1 Scope 2 Definitions permeability air flow capacity standard air flow capacity (SAF) 3 Principle 4 Apparatus 4.1 Test equipment 4.2 Air supply 4.3 Pressure regulator 4.4 Thermal mass flow sensor 4.5 Pressure sensor |
6 | 4.6 Test piece temperature indication 4.7 Programmable control furnace Figure 1 – Configuration of test equipment |
7 | Figure 2 – Pressure-tight thermocouple/T-piece adaptor for thermocouple entry into air stream |
8 | Figure 3 – Detail of T-piece |
9 | Figure 4 – Location of test piece |
10 | 5 Number and form of test pieces 5.1 Number 5.2 Test piece former 5.3 Shelling 5.4 Burn-out |
11 | Figure 5 – Sample former 6 Test procedure Table 1 – Test procedure: possible options 7 Shell characterization: procedure A 7.1 Measurement of shell test pieces 7.2 Connecting test piece to apparatus and performing leak checks |
12 | Figure 6 – Four sample diameter measurement points 7.3 Furnace controller |
13 | 7.4 Test pressure 7.5 Recording data 8 Production/quality control procedure on a fired shell: procedure B 9 Production/quality control procedure on an unfired shell: procedure C |
14 | 10 Calculation of results |
15 | 11 Test report |
16 | Annex A (informative) Alternative calculation methods Annex B (informative) Convention for tabular presentation of results Table B.1 – Temperature ramp phase |
17 | Table B.2 – Temperature dwell phase at 1 200 °C Annex C (informative) Convention of graphical presentation |
18 | Figure C.1 – Example of graphical presentation |