Construction products. Assessment of release of dangerous substances. Determination of emissions into indoor air of ammonia from cellulose insulation at 90 % RH

Published By Publication Date Number of Pages
BSI 2018 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Technical Report specifies a method for the determination of ammonia from cellulose insulation products at 90% relative humidity (RH). This document is based on the existing prEN 16516 standard which provides an horizontal reference method for the determination of emissions of regulated dangerous substances from construction products into indoor air.

PDF Catalog

PDF Pages PDF Title
2 undefined
8 1 Scope
2 Normative references
3 Terms and definitions
3.1 Terms relating to sampling and products
9 3.2 Terms relating to emissions into indoor air and associated laboratory testing
11 3.3 Terms relating to determination of emitted substances
4 Intended conditions of use, emission scenarios and European reference room
4.1 Intended conditions of use and emission scenario
4.2 Reference room and emission scenario
4.2.1 General
12 4.2.2 Dimensions and loading factors in the reference room
13 4.2.3 Ventilation in the reference room
4.2.4 Climate conditions in the reference room
4.3 Time schedule of emission(s) determination
5 Product sampling and transport to the laboratory
14 6 Handling of product samples in the laboratory
6.1 Storage of sample in the testing laboratory
6.2 Preparation of the test specimen
7 Test chamber conditions
7.1 Principles
15 7.2 Dimensions of test specimen
7.3 Loading factor
7.4 Ventilation
7.5 Air velocity
7.6 Cleanliness of test chamber
7.7 Testing climate (temperature, relative humidity of supply air)
16 7.8 Storage of test specimen
7.9 Large products
7.10 Volume of test chamber
7.11 Placement of test specimen in test chamber
17 8 Determination of ammonia in test chamber air
9 Calculation of specific emission rates and expression of results at the reference room
19 10 Reporting for the reference method
10.1 General
10.2 Sampling
10.3 Handling of samples in the laboratory, preparation of test specimen
10.4 Test chamber conditions
10.5 Determination of ammonia in test chamber air
20 11 Indirect methods
21 Annex A (informative)Examples of indirect methods (also called simplified, screening, secondary, derived or alternative methods)
A.1 General
A.2 Indirect methods‐emissions testing
BSI PD CEN/TR 17304:2018