{"id":195062,"date":"2024-10-19T12:22:45","date_gmt":"2024-10-19T12:22:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/aci-526r-2019\/"},"modified":"2024-10-25T04:53:32","modified_gmt":"2024-10-25T04:53:32","slug":"aci-526r-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/aci\/aci-526r-2019\/","title":{"rendered":"ACI 526R 2019"},"content":{"rendered":"

This guide is intended for use by architects, engineers, contractors, building officials, and manufacturers. Its purpose is to present, in a single source, information that can help those individuals design, specify, and construct with factory-reinforced panels of autoclaved aerated concrete (AAC). In this guide, introductory information on AAC is first presented, followed by a description of its manufacture, guidance on structural design using reinforced panels, and guidance on construction with such panels. The body of this guide ends with an extensive background chapter on the material characteristics of AAC and the structural behavior and design of AAC elements. Keywords: autoclaved aerated concrete; design; sustainability; shear wall<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nTITLE PAGE <\/td>\n<\/tr>\n
4<\/td>\nCHAPTER 1\u2014INTRODUCTION
1.1\u2014Introduction
1.2\u2014Historical background of AAC
1.3\u2014Scope and objectives of this guide <\/td>\n<\/tr>\n
5<\/td>\nCHAPTER 2\u2014NOTATION AND DEFINITIONS
2.1\u2014Notation
2.2\u2014Definitions <\/td>\n<\/tr>\n
6<\/td>\nCHAPTER 3\u2014TYPICAL MATERIAL AND THERMAL CHARACTERISTICS AND MANUFACTURE OF AAC
3.1\u2014Materials used in manufacturing of AAC
3.2\u2014Typical mechanical and thermal characteristics of AAC
3.3\u2014Thermal considerations <\/td>\n<\/tr>\n
8<\/td>\n3.4\u2014Manufacture of AAC <\/td>\n<\/tr>\n
9<\/td>\n3.5\u2014Typical dimensions of AAC units <\/td>\n<\/tr>\n
10<\/td>\n3.6\u2014Dimensional tolerances
3.7\u2014Identification and marking of AAC units
CHAPTER 4\u2014STRUCTURAL DESIGN OF REINFORCED AAC PANELS
4.1\u2014Applications of AAC panels
4.2\u2014Overview of proposed design provisions for reinforced AAC panels <\/td>\n<\/tr>\n
12<\/td>\nCHAPTER 5\u2014HANDLING, ERECTION, AND CONSTRUCTION WITH AAC PANELS
5.1\u2014Handling of AAC panels
5.2\u2014Erection of AAC wall panels
5.3\u2014Erection of AAC floor and roof panels <\/td>\n<\/tr>\n
13<\/td>\n5.4\u2014Electrical and plumbing installations in AAC
5.5\u2014Exterior finishes for AAC
5.6\u2014Interior finishes for AAC panels
CHAPTER 6\u2014TECHNICAL JUSTIFICATION FOR PROPOSED DESIGN PROVISIONS
6.1\u2014Key mechanical characteristics of AAC <\/td>\n<\/tr>\n
22<\/td>\n6.2\u2014Bond strength between factory-installed wire reinforcement and AAC <\/td>\n<\/tr>\n
24<\/td>\n6.3\u2014Flexural design of AAC beams <\/td>\n<\/tr>\n
25<\/td>\n6.4\u2014Control of deflections <\/td>\n<\/tr>\n
26<\/td>\n6.5\u2014Shear design of AAC beam elements
6.6\u2014Design of AAC shear walls <\/td>\n<\/tr>\n
40<\/td>\n6.7\u2014Behavior of AAC panels under eccentric axial compression
6.8\u2014Special provisions to avoid longitudinal cracking at location of vertical reinforcement <\/td>\n<\/tr>\n
45<\/td>\n6.9\u2014Design of AAC diaphragms <\/td>\n<\/tr>\n
49<\/td>\nCHAPTER 7\u2014REFERENCES <\/td>\n<\/tr>\n
50<\/td>\nAuthored documents <\/td>\n<\/tr>\n
52<\/td>\nAPPENDIX A
A.1\u2014Example 1: Design of AAC floor panel <\/td>\n<\/tr>\n
58<\/td>\nA.2\u2014Example 2: Design of AAC shear wall <\/td>\n<\/tr>\n
60<\/td>\nA.3\u2014Example 3: Design of AAC diaphragm <\/td>\n<\/tr>\n
64<\/td>\nA.4\u2014Example 4: Design of load-bearing vertical wall panel subjected to eccentric gravity and out-of-plane wind loads <\/td>\n<\/tr>\n
69<\/td>\nA.5\u2014Example 2: design of AAC shear wall (metric units) <\/td>\n<\/tr>\n
73<\/td>\nAPPENDIX B\u2014TYPICAL DESIGN DETAILS
B.1\u2014Cladding wall panel systems <\/td>\n<\/tr>\n
78<\/td>\nB.2\u2014Load-bearing vertical wall panel systems <\/td>\n<\/tr>\n
81<\/td>\nB.3\u2014Floor and roof details <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

526R-19: Guide for Design and Construction with Autoclaved Aerated Concrete Panels<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ACI<\/b><\/a><\/td>\n2019<\/td>\n88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":195067,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2650],"product_tag":[],"class_list":{"0":"post-195062","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-aci","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/195062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/195067"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=195062"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=195062"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=195062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}