{"id":240935,"date":"2024-10-19T15:46:35","date_gmt":"2024-10-19T15:46:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-7870-4-122001\/"},"modified":"2024-10-25T10:32:38","modified_gmt":"2024-10-25T10:32:38","slug":"bs-7870-4-122001","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-7870-4-122001\/","title":{"rendered":"BS 7870-4.12:2001"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | BRITISH STANDARD <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Committees responsible for this British\ufffdStandard <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | 1 Scope 2 Normative references 3 Voltage designation <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 4 Construction and dimensions 4.1 Conductors 4.2 Screens and insulation 4.3 Water blocking tape 4.4 Copper foil sheath <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 4.5 Oversheath 4.6 Triplex cables 4.7 Marking <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4.8 End sealing 4.9 Dimensions Table 1 5 Tests <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Table 2 <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 6 Routine tests 6.1 Spark test 6.2 Conductor resistance 6.3 Copper foil sheath resistance Table 3 6.4 Voltage test 6.5 Partial discharge test 6.6 Cable markings 7 Sample tests 7.1 Conductor material and construction 7.2 Conductor screen 7.3 Insulation <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 7.4 Circularity of insulated core 7.5 Insulation screen 7.6 Irregularities of insulation and screen 7.7 Water blocking tape 7.8 Copper foil sheath 7.9 Oversheath 7.10 Bending test\/4\ufffdh voltage test <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 8 Type tests 8.1 Material tests Table 4 <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Table 5 <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Table 6 8.2 Sequential electrical tests <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Table 7 Table 8 8.3 Long term test 8.4 Short-circuit test 8.5 Earth fault spiking test <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Annex A (informative) Guidance on selection of single core copper foil sheath cables Table A.1 Information to be specified by the user <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex B (informative) Guidance on type tests General Type tests on cables Compatibility test Type tests on components Annex C (informative) Water penetration test Test piece Test <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Figure 1 Water penetration test <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Annex D (informative) Peel strength of copper foil overlap Figure D.1 Peel strength of copper foil overlap <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Annex E (informative) Sidewall pressure test Figure E.1 Sidewall pressure test Table E.1 Sidewall pressure <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex F (normative) Impact test Figure F.1 Impact test <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex G (normative) Earth fault spiking test Objective Spiking test sample Electrical circuit Spiking procedure Test procedure <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Number of samples\/tests Examination <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV – Single core 11 kV copper foil sheath cables – Section 4.12: single core 11 kV copper foil sheath cables<\/b><\/p>\n |