{"id":244682,"date":"2024-10-19T16:04:49","date_gmt":"2024-10-19T16:04:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61326-3-22018\/"},"modified":"2024-10-25T11:04:14","modified_gmt":"2024-10-25T11:04:14","slug":"bs-en-iec-61326-3-22018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61326-3-22018\/","title":{"rendered":"BS EN IEC 61326-3-2:2018"},"content":{"rendered":"
This part of IEC 61326<\/span> <\/span> covers all equipment within the scope of IEC 61326\u20111<\/span> <\/span>, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508<\/span> <\/span> with SIL 1-3.<\/p>\n The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, and based on the requirements of the process industry, specifically chemical\/petrochemical\/pharmaceutical manufacturing plants using the mitigation measures given in Annex C<\/span>. The difference between the electromagnetic environment covered by this document compared to the general industrial environment (see IEC 61326\u20113\u20111<\/span> <\/span>) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment with test values that have been proven in practice.<\/p>\n The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics:<\/p>\n industrial area with limited access;<\/p>\n<\/li>\n limited use of mobile transmitters;<\/p>\n<\/li>\n dedicated cables for power supply and control, signal or communication lines;<\/p>\n<\/li>\n separation between power supply and control, signal or communication cables;<\/p>\n<\/li>\n factory building mostly consisting of metal construction;<\/p>\n<\/li>\n overvoltage\/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices);<\/p>\n<\/li>\n pipe heating systems driven by AC main power;<\/p>\n<\/li>\n no high-voltage substation close to sensitive areas;<\/p>\n<\/li>\n presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power;<\/p>\n<\/li>\n competent staff;<\/p>\n<\/li>\n periodical maintenance of equipment and systems;<\/p>\n<\/li>\n mounting and installation guidelines for equipment and systems.<\/p>\n<\/li>\n<\/ul>\n Equipment and systems considered as \u201cproven-in-use\u201d according to IEC 61508<\/span> <\/span> or \u201cprior use\u201d according to IEC 61511<\/span> <\/span> are excluded from the scope of this document.<\/p>\n Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of this document.<\/p>\n Electrical equipment for measurement, control and laboratory use. EMC requirements – Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety). Industrial applications with specified electromagnetic environment<\/b><\/p>\n\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 5<\/td>\n Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n \n 7<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 9<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 11<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 13<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 15<\/td>\n 3 Terms, definitions and abbreviations
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 18<\/td>\n 3.2 Abbreviations
4 General
5 EMC test plan
5.1 General <\/td>\n<\/tr>\n\n 19<\/td>\n 5.2 Instruction for testing
5.3 Configuration of EUT during testing
5.3.1 General
5.3.2 Composition of EUT
5.3.3 Assembly of EUT
5.3.4 I\/O ports <\/td>\n<\/tr>\n\n 20<\/td>\n 5.3.5 Auxiliary equipment (AE)
5.3.6 Cabling and earthing (grounding)
5.4 Operation conditions of EUT during testing
5.4.1 Operation modes
5.4.2 Environmental conditions
5.4.3 EUT software during test
5.5 Specification of performance criteria
5.6 Test description <\/td>\n<\/tr>\n\n 21<\/td>\n 6 Performance criteria
6.1 General
6.2 Performance criteria A, B and C
6.3 Performance criterion DS
6.3.1 Definition of performance criterion DS
6.3.2 Application of the performance criterion DS <\/td>\n<\/tr>\n\n 22<\/td>\n 6.3.3 Aspects to be considered during application of performance criterion DS
7 Immunity requirements
Tables
Table 1 \u2013 Reaction of EUT during test <\/td>\n<\/tr>\n\n 23<\/td>\n Table 2 \u2013 Immunity test requirements \u2013 Enclosure port
Table 3 \u2013 Immunity test requirements \u2013 Input and output AC power ports <\/td>\n<\/tr>\n\n 24<\/td>\n Table 4 \u2013 Immunity test requirements \u2013 Input and output DC power ports
Table 5 \u2013 Immunity test requirements \u2013 I\/O signal\/control ports
Table 6 \u2013 Immunity test requirements \u2013 I\/O signal\/controlports connected directly to power supply networks <\/td>\n<\/tr>\n\n 25<\/td>\n 8 Test set-up and test philosophy for EUT with functions intended for safety applications
8.1 Testing of safety-related systems and equipment intended to be used in safety-related systems
8.2 Test philosophy for equipment intended for use in safety-related systems
Table 7 \u2013 Immunity test requirements \u2013 Functional earth port <\/td>\n<\/tr>\n\n 26<\/td>\n 8.3 Test philosophy for safety-related systems
8.4 Test configuration and test performance <\/td>\n<\/tr>\n\n 27<\/td>\n 8.5 Monitoring
9 Test results and test report <\/td>\n<\/tr>\n\n 28<\/td>\n Figures
Figure 1 \u2013 Typical test set-up for equipment intended for use in safety-related system, tested as stand-alone equipment or entire system <\/td>\n<\/tr>\n\n 29<\/td>\n Figure 2 \u2013 Typical test set-up for equipment intended for use in a safety-related system integrated into a representative safety-related system during test <\/td>\n<\/tr>\n \n 30<\/td>\n Annexes
Annex A (informative) Approaches on how to apply IEC 61326-3 series <\/td>\n<\/tr>\n\n 31<\/td>\n Figure A.1 \u2013 Correlation between the standardsIEC 61326-1, IEC 61326-2-x, IEC 61326-3-1 and IEC 61326-3-2 <\/td>\n<\/tr>\n \n 32<\/td>\n Annex B (informative) Evaluation of electromagnetic phenomena <\/td>\n<\/tr>\n \n 33<\/td>\n Table B.1 \u2013 General considerations for the application of electromagnetic phenomena for functional safety in industrial applications with specified electromagnetic environment (examples) <\/td>\n<\/tr>\n \n 34<\/td>\n Annex C (normative) Specified electromagnetic environment
C.1 General
C.2 Industrial area with limited access
C.3 Limited use of mobile transmitters <\/td>\n<\/tr>\n\n 35<\/td>\n C.4 Dedicated cables for power supply and control, signal or communication lines
C.5 Separation between power supply and control, signal or communication cables <\/td>\n<\/tr>\n\n 36<\/td>\n C.6 Factory building mostly consisting of metal construction
C.7 Overvoltage\/lightning protection by appropriate measures
Figure C.1 \u2013 Recommended cable layouts for different categories <\/td>\n<\/tr>\n\n 37<\/td>\n C.8 Pipe heating systems driven by AC mains
C.9 No high-voltage substations close to sensitive areas
C.10 Presence of low-power devices using ISM frequencies according to CISPR 11
C.11 Competent staff
C.12 Periodic maintenance of equipment and systems
C.13 Installation guidelines for equipment and systems <\/td>\n<\/tr>\n\n 38<\/td>\n Annex D (informative) Example of immunity levels in the process industry <\/td>\n<\/tr>\n \n 39<\/td>\n Table D.1 \u2013 Immunity test requirements for equipment intended for use in industrial locations with a specified electromagnetic environment according to NE 21 <\/td>\n<\/tr>\n \n 41<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2018<\/td>\n 44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":244687,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[385,2641],"product_tag":[],"class_list":{"0":"post-244682","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-25-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/244682","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/244687"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=244682"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=244682"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=244682"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}