{"id":424273,"date":"2024-10-20T06:50:56","date_gmt":"2024-10-20T06:50:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-138232020a12022\/"},"modified":"2024-10-26T12:52:04","modified_gmt":"2024-10-26T12:52:04","slug":"bs-en-138232020a12022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-138232020a12022\/","title":{"rendered":"BS EN 13823:2020+A1:2022"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
8<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
10<\/td>\n4 Test facility
4.1 General
4.2 Test room <\/td>\n<\/tr>\n
11<\/td>\n4.3 Materials <\/td>\n<\/tr>\n
12<\/td>\n4.4 Test apparatus <\/td>\n<\/tr>\n
14<\/td>\n4.5 Smoke exhaust system
4.6 General measurement section equipment <\/td>\n<\/tr>\n
15<\/td>\n4.7 Other general equipment <\/td>\n<\/tr>\n
16<\/td>\n5 Test specimen
5.1 Dimensions of specimen <\/td>\n<\/tr>\n
17<\/td>\n5.2 Mounting of specimen
5.2.1 Mounting as in end use application
5.2.2 Standard mounting <\/td>\n<\/tr>\n
19<\/td>\n5.3 Installation of the specimen wings in the trolley <\/td>\n<\/tr>\n
20<\/td>\n5.4 Number of specimens
6 Conditioning
7 Principle <\/td>\n<\/tr>\n
21<\/td>\n8 Test procedure
8.1 General
8.2 Testing operations <\/td>\n<\/tr>\n
22<\/td>\n8.3 Visual observation and manual recording of data
8.3.1 General
8.3.2 Pre-test conditions
8.3.3 Lateral flame spread on the long wing
8.3.4 Flaming particles or droplets <\/td>\n<\/tr>\n
24<\/td>\n8.3.5 End of test conditions
8.3.6 Recorded events
8.4 Automated recording of data <\/td>\n<\/tr>\n
25<\/td>\n8.5 Early termination of test
9 Expression of results <\/td>\n<\/tr>\n
26<\/td>\n10 Test report <\/td>\n<\/tr>\n
27<\/td>\nAnnex A (normative)Calculation procedures
A.1 General
A.1.1 General remarks
A.1.1.1 General
A.1.1.2 Notation <\/td>\n<\/tr>\n
28<\/td>\nA.1.2 Calculations to be performed on the test data
A.1.3 Calculations to be performed on calibration data
A.1.4 Standard data set
A.2 Synchronization of data <\/td>\n<\/tr>\n
30<\/td>\nA.3 Checking equipment response
A.3.1 Temperature readings
A.3.2 Drift in gas concentration measurement
A.3.3 Drift in light attenuation measurement <\/td>\n<\/tr>\n
31<\/td>\nA.4 Exposure period
A.5 Heat output
A.5.1 Calculation of heat release rate (HRR)
A.5.1.1 Total HRR of specimen and burner: HRRtotal <\/td>\n<\/tr>\n
33<\/td>\nA.5.1.2 HRR of the burner <\/td>\n<\/tr>\n
34<\/td>\nA.5.1.3 HRR of the specimen
A.5.1.4 Calculation of HRR30s <\/td>\n<\/tr>\n
35<\/td>\nA.5.2 Calculation of THR(t) and THR600s
A.5.3 Calculation of FIGRA0,2MJ and FIGRA0,4MJ (fire growth rate indices) <\/td>\n<\/tr>\n
36<\/td>\nA.6 Smoke production
A.6.1 Calculation of smoke production rate (SPR)
A.6.1.1 Total SPR of specimen and burner: SPRtotal <\/td>\n<\/tr>\n
37<\/td>\nA.6.1.2 SPR of the burner <\/td>\n<\/tr>\n
38<\/td>\nA.6.1.3 SPR of the specimen <\/td>\n<\/tr>\n
39<\/td>\nA.6.1.4 Calculation of SPR60s
A.6.2 Calculation of TSP(t) and TSP600s <\/td>\n<\/tr>\n
40<\/td>\nA.6.3 Calculation of SMOGRA (smoke growth rate index) <\/td>\n<\/tr>\n
41<\/td>\nA.7 Calculations for calibrations \u2013 Propane heat release <\/td>\n<\/tr>\n
42<\/td>\nAnnex B (informative)Precision of test method
B.1 General remarks and results <\/td>\n<\/tr>\n
43<\/td>\nB.2 Calculation of test results
B.3 Statistical analysis <\/td>\n<\/tr>\n
44<\/td>\nB.4 Statistical results <\/td>\n<\/tr>\n
49<\/td>\nAnnex C (normative)Calibration procedures
C.1 Procedures for separate pieces of equipment
C.1.1 General
C.1.2 Oxygen analyser adjustment
C.1.3 Oxygen analyser output noise and drift
C.1.3.1 General
C.1.3.2 Procedure <\/td>\n<\/tr>\n
50<\/td>\nC.1.3.3 Criteria
C.1.3.4 Calibration report
C.1.4 Carbon dioxide analyser adjustment
C.1.5 Light system calibration
C.1.5.1 General
C.1.5.2 Stability check <\/td>\n<\/tr>\n
51<\/td>\nC.1.5.3 Optical filter check
C.2 System response calibrations
C.2.1 Burner switch response time <\/td>\n<\/tr>\n
53<\/td>\nC.2.2 Burner heat output step calibration
C.2.2.1 General
C.2.2.2 Procedure <\/td>\n<\/tr>\n
54<\/td>\nC.2.2.3 Calculations <\/td>\n<\/tr>\n
56<\/td>\nC.2.2.4 Criteria
C.2.2.5 Calibration report
C.2.3 Heptane calibration
C.2.3.1 General <\/td>\n<\/tr>\n
57<\/td>\nC.2.3.2 Procedure
C.2.3.3 Calculations <\/td>\n<\/tr>\n
58<\/td>\nC.2.3.4 Criteria
C.2.3.5 Calibration report
C.2.4 Velocity profile factor kt,v
C.2.4.1 General
C.2.4.2 Measurement specifications <\/td>\n<\/tr>\n
59<\/td>\nC.2.4.3 Actions <\/td>\n<\/tr>\n
60<\/td>\nC.2.4.4 Calculation of kt,v
C.2.4.5 Measurement report
C.2.5 Flow factor kt <\/td>\n<\/tr>\n
61<\/td>\nAnnex D (informative)Calibration procedures
D.1 Procedures for separate pieces of equipment
D.1.1 General
D.1.2 Oxygen analyser adjustment
D.1.3 Carbon dioxide analyser adjustment <\/td>\n<\/tr>\n
62<\/td>\nD.1.4 Check of propane mass flow controller
D.1.4.1 General
D.1.4.2 Procedure
D.1.4.3 Criterion
D.1.5 Optical filter check
D.1.5.1 General
D.1.5.2 Procedures <\/td>\n<\/tr>\n
63<\/td>\nD.1.5.3 Criterion
D.2 Check of the thermal attack on the specimens
D.2.1 General
D.2.2 Procedure <\/td>\n<\/tr>\n
64<\/td>\nAnnex E (normative)Design drawings <\/td>\n<\/tr>\n
99<\/td>\nAnnex F (informative)Data file format <\/td>\n<\/tr>\n
102<\/td>\nAnnex G (informative)Record sheet <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Reaction to fire tests for building products. Building products excluding floorings exposed to the thermal attack by a single burning item<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2023<\/td>\n104<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":424283,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,2641],"product_tag":[],"class_list":{"0":"post-424273","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/424273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/424283"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=424273"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=424273"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=424273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}