ASTM-A861:2017 Edition
$58.50
A861-04(2017) Standard Specification for High-Silicon Iron Pipe and Fittings
Published By | Publication Date | Number of Pages |
ASTM | 2017 | 26 |
ASTM A861-04-Reapproved2017
Historical Standard: Standard Specification for High-Silicon Iron Pipe and Fittings
ASTM A861
Scope
1.1 This specification covers high-silicon iron pipe and pipe fittings intended for corrosion-resistant service for both above- and below-grade construction.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 Pipe and pipe fittings shall be the no-hub (MJ) or the hub and plain end design.
1.4 Pipe and pipe fittings shall be of the sizes specified in Table 1 and Table 2 and Figs. 1-71 or other sizes that shall be permitted to conform to the requirements given herein.
TABLE 1 Tolerances for High-Silicon Iron Hub/Plain-End Pipe
Note 1: 1 in. = 25.4 mm.
TABLE 2 Tolerances for High-Silicon Iron Fittings
Note 1: 1 in. = 25.4 mm.
TABLE 3 Chemical Composition
FIG. 1 No-Hub Pipe (MJ)
Note 1: 1 in. = 25.4 mm.
FIG. 2 Quarter Bends
Note 1: 1 in. = 25.4 mm.
FIG. 3 Sixth Bends
Note 1: 1 in. = 25.4 mm.
FIG. 4 Return Bends
Note 1: 1 in. = 25.4 mm.
FIG. 5 Double-Branch Quarter Bend
Note 1: 1 in. = 25.4 mm.
FIG. 6 Eight Bends
Note 1: 1 in. = 25.4 mm.
FIG. 7 Sixteenth Bends
Note 1: 1 in. = 25.4 mm.
FIG. 8 Long-Sweep Quarter Bends
FIG. 9 Sanitary Y Branches
Note 1: 1 in. = 25.4 mm.
FIG. 10 Double-Branch Sanitary Y
Note 1: 1 in. = 25.4 mm.
FIG. 11 Sanitary Combination Y and 1/8 Bend
Note 1: 1 in. = 25.4 mm.
FIG. 12 Double-Branch Sanitary Combination Y and 1/8 Bend
Note 1: 1 in. = 25.4 mm.
FIG. 13 Sanitary T Branches
Note 1: 1 in. = 25.4 mm.
FIG. 14 Double-Branch Sanitary T
Note 1: 1 in. = 25.4 mm.
FIG. 15 Sanitary Running Traps
Note 1: 1 in. = 25.4 mm.
FIG. 16 Sanitary P Traps
Note 1: 1 in. = 25.4 mm.
FIG. 17 Swivel Trap P-Style, Short
Note 1: 1 in. = 25.4 mm.
FIG. 18 Swivel Trap P-Style, Long
Note 1: 1 in. = 25.4 mm.
FIG. 19 Swivel Type-S Style, Long
Note 1: 1 in. = 25.4 mm.
FIG. 20 Centrifugal Drum Trap P Swivel Type
FIG. 21 Centrifugal Drum Trap S Swivel Type
Note 1: 1 in. = 25.4 mm.
FIG. 22 Combination Cleanout and Test Tees
Note 1: 1 in. = 25.4 mm.
FIG. 23 Coupling
Note 1: 1 in. = 25.4 mm.
FIG. 24 Pipe Plugs
Note 1: 1 in. = 25.4 mm.
FIG. 25 Cleanout Plugs
Note 1: 1 in. = 25.4 mm.
FIG. 26 Adapter/Hub to No-Hub
Note 1: 1 in. = 25.4 mm.
FIG. 27 Reducers-Increasers
Note 1: 1 in. = 25.4 mm.
FIG. 28 Sink Outlet
Note 1: 1 in. = 25.4 mm.
FIG. 29 Sink Overflows
Note 1: 1 in. = 25.4 mm.
FIG. 30 Threaded Adapters
Note 1: 1 in. = 25.4 mm.
FIG. 31 Trap Cleanout Details
Note 1: 1 in. = 25.4 mm.
FIG. 32 Adapter โ No-Hub and Split Flange
Note 1: Flange dimensions are 150 lb ANSI standard.
Note 2: 1 in. = 25.4 mm.
FIG. 33 MJ to Lead Adapter
Note 1: 1 in. = 25.4 mm.
FIG. 34 Floor Drains
Note 1: 1 in. = 25.4 mm.
FIG. 35 Hub and Plain End Pipe
Note 1: 1 in. = 25.4 mm.
FIG. 36 Straight Tees
Note 1: 1 in. = 25.4 mm.
FIG. 37 Sanitary T Branches
Note 1: 1 in. = 25.4 mm.
FIG. 38 Sanitary Y Branches
Note 1: 1 in. = 25.4 mm.
FIG. 39 Double-Branch Sanitary Tee
FIG. 40 Double-Branch Sanitary Y
Note 1: 1 in. = 25.4 mm.
FIG. 41 Double-Branch Sanitary Combination Y and 1/8 Bend (T-Y)
Note 1: 1 in. = 25.4 mm.
FIG. 42 Short-Sweep Quarter Bends
Note 1: 1 in. = 25.4 mm.
FIG. 43 Long-Sweep Quarter Bends
Note 1: 1 in. = 25.4 mm.
FIG. 44 Sanitary Combination Y and 1/8 Bend (T-Y)
Note 1: 1 in. = 25.4 mm.
FIG. 45 Quarter Bends
Note 1: 1 in. = 25.4 mm.
FIG. 46 Sixth Bends
Note 1: 1 in. = 25.4 mm.
FIG. 47 Eighth Bends
Note 1: 1 in. = 25.4 mm.
FIG. 48 Sixteenth Bends
Note 1: 1 in. = 25.4 mm.
FIG. 49 Sanitary Increasers
Note 1: 1 in. = 25.4 mm.
FIG. 50 Hub Strainers
Note 1: 1 in. = 25.4 mm.
FIG. 51 Sanitary Reducers
Note 1: 1 in. = 25.4 mm.
FIG. 52 Double Hubs
Note 1: 1 in. = 25.4 mm.
FIG. 53 Pipe Plugs
Note 1: 1 in. = 25.4 mm.
FIG. 54 Cleanout Plugs
Note 1: 1 in. = 25.4 mm.
FIG. 55 Adapter โ Plain End and Split Flange
Note 1: 1 in. = 25.4 mm.
FIG. 56 Adapter โ Hub and Split Flange
Note 1: 1 in. = 25.4 mm.
FIG. 57 Combination Cleanout and Test Tees
Note 1: 1 in. = 25.4 mm.
FIG. 58 Insertable Joints
Note 1: 1 in. = 25.4 mm.
FIG. 59 Backwater Valves
Note 1: 1 in. = 25.4 mm.
FIG. 60 Sanitary P Traps
Note 1: Depth of seal on all traps shall be 21/2 in.
Note 2: 1 in. = 25.4 mm.
FIG. 61 Sanitary S Traps
Note 1: Depth of seal on all traps shall be 21/2 in.
Note 2: 1 in. = 25.4 mm.
FIG. 62 Sanitary Running Traps
Note 1: Single hub vent is located on the inlet side. Depth of seal on 8- and 10-in. traps is 3 in. All others 21/2 in.
Note 2: 1 in. = 25.4 mm.
FIG. 63 Outside Caulk
Note 1: 1 in. = 25.4 mm.
FIG. 64 Outside Caulk with Basin
Note 1: 1 in. = 25.4 mm.
FIG. 65 Inside Caulk
Note 1: 1 in. = 25.4 mm.
FIG. 66 Floor Drains
Note 1: 1 in. = 25.4 mm.
FIG. 67 Method of Installation
FIG. 68 Floor Drain Funnel Attachment
Note 1: 1 in. = 25.4 mm.
FIG. 69 No. 1, 2, 3, 4, and 5 Overflows
Note 1: 1 in. = 25.4 mm.
FIG. 70 Sink Outlet
Note 1: Furnished with flat loose strainer plates.
Note 2: 1 in. = 25.4 mm.
FIG. 71 Detailed Cross Section of Cleanout
Note 1: Traps can be supplied without cleanouts, as shown in the figure.
Note 2: 1 in. = 25.4 mm.
1.4.1 Pipe:
1.4.1.1 No-Hub (MJ) (Fig. 1):
1.4.1.2 Hub/Plain End (Fig.35):
1.4.2 Fitting (No-Hub) (MJ):
1.4.3 Fitting (Hub/Plain End):
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Keywords
corrosion resistant; fittings; high-silicon iron; hubless; hub/plain-end; no-hub; plain-end;
ICS Code
ICS Number Code 23.040.10 (Iron and steel pipes)
DOI: 10.1520/A0861-04R17