Soil, treated biowaste, sludge and waste. Digestion with a hydrochloric (HCl), nitric (HNO3) and tetrafluoroboric (HBF4) or hydrofluoric (HF) acid mixture for subsequent determination of elements
Published By | Publication Date | Number of Pages |
BSI | 2020 | 40 |
This document specifies three methods for the digestion of soil, treated biowaste, sludge and waste by the use of an acid mixture composed of hydrochloric (HCl), nitric (HNO3) and tetrafluoroboric (HBF4) or hydrochloric (HCl), nitric (HNO3) and hydrofluoric (HF) acid as the digestion solution. Digestion with these acids is effectively considered as a total decomposition of the sample. For a broad range of samples the extracted analyte concentrations will reflect the total content in the sample. This document is applicable for the following elements: Aluminium (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), cadmium (Cd), calcium (Ca), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), magnesium (Mg), manganese (Mn), mercury (Hg), molybdenum (Mo), nickel (Ni), phosphorus (P), potassium (K), selenium (Se), silver (Ag), sodium (Na), strontium (Sr), sulfur (S), tellurium (Te), thallium (Tl), tin (Sn), titanium (Ti), vanadium (V), and zinc (Zn). This document can also be applied for the digestion of other elements, provided the user has verified the applicability.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
8 | 4 Principle |
9 | 5 Interferences and sources of errors 5.1 General information 5.2 Closed vessel system for microwave digestion 6 Reagents |
10 | 7 Apparatus |
11 | 8 Procedure 8.1 General 8.2 Blank test 8.3 Method A: Heating block digestion using HCl, HNO3 and HBF4 |
12 | 8.4 Method B: Microwave digestion 8.4.1 Method B1: Digestion with HBF4, HNO3 and HCl using microwave heating, temperature-controlled, closed vessels |
13 | 8.4.2 Method B2: Digestion with HF, HNO3 and HCl using microwave heating, power-controlled, closed vessels |
14 | 9 Test report |
15 | Annex A (normative)Calibration of the power adjustment |
16 | Annex B (informative)Repeatability and reproducibility data – Method A and B1 B.1 Inter-laboratory study B.2 Selection of laboratories B.3 Selection of samples |
17 | B.4 Experimental B.5 Results B.6 Conclusions |
25 | Annex C (informative)Repeatability and reproducibility data – Method B2 C.1 Inter-laboratory study C.1.1 General C.1.2 Selection of laboratories C.1.3 Selection of samples |
26 | C.1.4 Experimental C.1.5 Results C.1.6 Conclusions |
33 | C.2 Robustness study C.2.1 General |
34 | C.2.2 Analytical method |
35 | C.2.3 Results |
37 | C.2.4 Conclusion |