Aerospace series. Fibre reinforced plastics. Test method. Determination of notched, unnotched and filled hole compression strength
Published By | Publication Date | Number of Pages |
BSI | 2015 | 16 |
This standard defines a method to be used to determine the compression strength of notched, unnotched and filled hole fibre reinforced plastics.
It is applicable to composite laminates with unidirectional layers or woven fabric reinforcement.
This standard does not give any direction necessary to meet health and safety requirements. It is the responsibility of the user of this standard to consult and establish appropriate health and safety precautions.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
5 | European foreword |
6 | 1 Scope 2 Normative references 3 Terms and definitions |
7 | 4 Principle of the method 5 Designation of the method 6 Apparatus 6.1 Compression test machine accurate to within 1 % equipped with facilities to record maximum load and fitted with suitable grips or used with compression jig featuring a grip and movement alignment system. 6.2 Chamber adapted to the machine to carry out tests at temperature. The temperature shall be maintained within ( 3 C. 6.3 Timer. 6.4 Thermocouple with recorder to monitor temperature for tests at other than ambient. |
8 | 6.5 Flat faced micrometre with 6 mm diameter faces, accurate to 0,01 mm. 6.6 Vernier calliper accurate to the nearest 0,1 mm. 7 Test specimen 7.1 Specimen description 7.2 Test specimen preparation 7.3 Tabs 7.4 Number of specimens 7.5 Ageing 8 Procedure 8.1 Conditioning |
9 | 8.2 Determination of dimensions 8.3 Test at ambient temperature 8.4 Test at temperature other than ambient 9 Presentation of the results 9.1 Tensile strength (c |
10 | 9.2 Nominal tensile strength (nc 9.3 KT1 value (see 3.4) 9.4 KT2 value (see 3.5) |
11 | 10 Test report 10.1 Complete identification of the material tested, including at least type, source, manufacturer’s code number, fibre areal weight, filament count, processing details. 10.2 All details regarding specimen preparation (including when applicable: tabs material, tabs adhesive and curing condition of this adhesive). 10.3 The measured specimen dimensions. 10.4 Ageing and/or exposure condition prior to the test. 10.5 Date of test, facility and identification of individuals performing the tests. 10.6 Equipment, method and test parameters used. 10.7 Individual values, mean value and standard deviation of tensile strength for notched, unnotched and filled specimen. 10.8 KT values. 10.9 Any incident which may have affected the results and any deviation from this standard. |