Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Examinations and measurements. Angular misalignment between ferrule bore axis and ferrule axis for cylindrical ferrules

Published By Publication Date Number of Pages
BSI 2019 20
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61300-3-54:2019 describes the procedure to measure the angular misalignment between the ferrule bore axis and the outside diameter datum axis of a cylindrical ferrule. Keywords: ferrule bore, angular misalignment

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
8 FOREWORD
10 1 Scope
2 Normative references
3 Terms and definitions
11 4 General description
5 Apparatus
5.1 General
5.2 Pin gauge
Figures
Figure 1 – Angular misalignment between ferrule bore axis and ferrule outside diameter datum axis
Figure 2 – Example of test apparatus
12 5.3 Ferrule holder
5.4 Microscope with video camera
5.5 Precision alignment stage
5.6 Display
5.7 Computer
6 Procedure
13 7 Details to be specified
14 Annex A (informative)Measurement uncertainty
A.1 General
A.2 Precision alignment stage accuracy
Figure A.1 – Diagram of error caused by the precision alignment stage accuracy
15 A.3 Misalignment between ferrule holder axis and camera axis
A.4 Image plane resolution per pixel
Figure A.2 – Diagram of error caused by the misalignment betweenthe ferrule holder axis and the camera axis
16 A.5 Ferrule bore eccentricity
A.6 Clearance between ferrule bore diameter and gauge diameter
Figure A.3 – Diagram of error caused by the image plane resolution per pixel
Figure A.4 – Diagram of error caused by the ferrule bore eccentricity
17 A.7 Summary of measurement uncertainty
Figure A.5 – Diagram of error caused by the clearance betweenthe ferrule bore diameter and the pin gauge diameter
Table A.1 – Example of measurement uncertainty summary
18 Bibliography