{"id":362652,"date":"2024-10-20T01:41:31","date_gmt":"2024-10-20T01:41:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-16840-22018-tc\/"},"modified":"2024-10-26T02:40:11","modified_gmt":"2024-10-26T02:40:11","slug":"bs-iso-16840-22018-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-16840-22018-tc\/","title":{"rendered":"BS ISO 16840-2:2018 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | compares BS ISO 16840\u20112:2018 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | TRACKED CHANGES Text example 1 \u2014 indicates added text (in green) <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | National foreword Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 200731 January2018. Amendments\/corrigenda issued since publication <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Wheelchair seating \u2014 <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | COPYRIGHT PROTECTED DOCUMENT <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Wheelchair seating \u2014 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3 Terms and definitions 3.1 3.1.1 3.1.2 3.23.1.2.1 <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3.2 4 Symbols and abbreviated terms l overall length t time for the recording period (associated units: s = seconds; d = days) hth cushion thickness 5 Apparatus 5.1 Loading rig <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.2 Rigid cushion loading indenter (RCLI) 5.3 Impact damping rigid cushion loading indenter (IDRCLI) 5.4 Force application rig 5.5 Displacement gauge 5.6 Impact damping rig <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Figure 1 \u2014 Loading rig showing the reference plane on the top surface of the RCLI in plain view and a displacement gauge <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Figure 2 \u2014 Impact damping rig <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.7 Loaded contour indenter (LCI) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.8 Seat cushion thickness measurement rig 65.9 Test environment <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Figure 3 \u2014 Loaded contour indenter 7.16.1 Choice of cushion 7.26.2 Preconditioning the cushion 7.36.3 Setup <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 87 Sequence of testing 8 Frictional properties 8.1 Rationale 8.2 Test method 8.3 Test report 9 Load-deflection and hysteresis test 9 Impact damping under normal loading conditions 9.1 Rationale <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 9.2 Test method <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure 4 \u2014 Typical result for impact damping test, plotting acceleration against time in milliseconds 9.3 Method of calculation <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 9.4 Test report <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 10 Frictional properties 10.1 Rationale 10.2 Test method 10.3 Test report 11 Impact damping under normal loading conditions 11.1 Rationale 11.2 Test method <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 1210 Recovery 12.110.1 Rationale 12.210.2 Test method <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 12.310.3 Test report <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 1311 Loaded contour depth and overload deflection 13.111.1 Rationale 13.211.2 Test method <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure 5 \u2014 Measurement method for concave and convex seat cushion top surfaces <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 13.311.3 Method of calculation 13.411.4 Test report 1412 Water spillage 14.112.1 Rationale 14.212.2 Test method 14.312.3 Test report 1513 Biocompatibility 15.113.1 Rationale 15.213.2 Test method <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 15.313.3 Test report 14.1 Rationale 14.2 Test method 14.3 Method of calculation <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 14.4 Test report 1615 Test report 1716 Disclosure requirement <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | (normative) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Figure A.1 \u2014 Assembly of components for RCLI <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Table A.1 \u2014 Cone and sphere dimensions <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Table B.1 \u2014 Typical ranges <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Annex C (informative) C.1 Apparatus C.1.1 Lateral and forward stiffnessmovement rig <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Figure C.1 \u2014 Apparatus to measureLateral and forward movement rig ready for testing lateral and forward stiffness <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | C.3 Sliding resistance C.3.1 Rationale C.3.2 Test method <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Annex D (informative) Table D.1 \u2014 Dimensional properties RCLI for alternatively sized cushions Table D.2 \u2014 Key parameters for use of RCLI for alternatively sized cushions <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Bibliography <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 4 Symbols and abbreviated terms 5 Apparatus 5.1 Loading rig <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 5.2 Rigid cushion loading indenter (RCLI) 5.3 Impact damping rigid cushion loading indenter (IDRCLI) 5.4 Force application rig 5.5 Displacement gauge 5.6 Impact damping rig <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 5.7 Loaded contour indenter (LCI) 5.8 Seat cushion thickness measurement rig 5.9 Test environment <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 6 Preparation of test cushion 6.1 Choice of cushion 6.2 Preconditioning the cushion <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 6.3 Setup 7 Sequence of testing 8 Frictional properties 8.1 Rationale 8.2 Test method 8.3 Test report 9 Impact damping under normal loading conditions 9.1 Rationale 9.2 Test method <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 9.3 Method of calculation 9.4 Test report 10 Recovery 10.1 Rationale 10.2 Test method <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 10.3 Test report <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | 11 Loaded contour depth and overload deflection 11.1 Rationale 11.2 Test method <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 11.3 Method of calculation <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 11.4 Test report 12 Water spillage 12.1 Rationale 12.2 Test method 12.3 Test report 13 Biocompatibility 13.1 Rationale 13.2 Test method 13.3 Test report 14 Hysteresis test 14.1 Rationale <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 14.2 Test method 14.3 Method of calculation 14.4 Test report 15 Test report <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | 16 Disclosure requirement <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex A (normative) Tapered uniform geometry RCLI <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Annex B (informative) Typical ranges for ISO 16840\u20112 tests and indicative cushion implications <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex C (informative) Horizontal stiffness and sliding resistance <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Annex D (informative) RCLIs for testing of alternatively sized cushions <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Wheelchair seating – Determination of physical and mechanical characteristics of seat cushions intended to manage tissue integrity<\/b><\/p>\n |