{"id":40291,"date":"2024-10-17T05:53:00","date_gmt":"2024-10-17T05:53:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-c761\/"},"modified":"2024-10-24T15:26:15","modified_gmt":"2024-10-24T15:26:15","slug":"astm-c761","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-c761\/","title":{"rendered":"ASTM-C761"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF 6<\/sub> . Most of these test methods are in routine use to determine conformance to UF 6<\/sub> specifications in the Enrichment and Conversion Facilities.<\/p>\n

1.2 The analytical procedures in this document appear in the following order:<\/p>\n

Note 1Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications.<\/p>\n

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (For specific safeguard and safety consideration statements, see Section 6.)<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents <\/td>\n<\/tr>\n
2<\/td>\nSignificance and Use
Reagents
Rejection
Safety Considerations <\/td>\n<\/tr>\n
3<\/td>\nScope
Scope
Summary of Test Method
Interferences
Apparatus
FIG. 1 <\/td>\n<\/tr>\n
4<\/td>\nReagents
Sampling
Procedure
FIG. 2 <\/td>\n<\/tr>\n
5<\/td>\nCalculation
Precision and Bias
Scope <\/td>\n<\/tr>\n
6<\/td>\nScope
Scope
Scope
Summary of Test Method
Interferences
Apparatus
Procedure
TABLE 2 <\/td>\n<\/tr>\n
7<\/td>\nCalculation
Reliability
Scope
Scope
Scope
Summary of Test Method
TABLE 3 <\/td>\n<\/tr>\n
8<\/td>\nApparatus
Reagents
Procedure
Calculation
FIG. 3 <\/td>\n<\/tr>\n
9<\/td>\nReliability
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
Procedure <\/td>\n<\/tr>\n
10<\/td>\nReliability
Scope
Scope
Scope <\/td>\n<\/tr>\n
11<\/td>\nScope
Scope
Scope
Scope
Scope
Summary of Test Method
Apparatus
Reagents <\/td>\n<\/tr>\n
12<\/td>\nProcedure
Reliability <\/td>\n<\/tr>\n
13<\/td>\nScope
Scope
Scope
Scope
Summary of Test Method
Apparatus
Reagents
Procedure
TABLE 4 <\/td>\n<\/tr>\n
14<\/td>\nCalculation
FIG. 4 <\/td>\n<\/tr>\n
15<\/td>\nReliability
Scope
Scope
Summary of Test Method
Apparatus
Reagents
Procedure <\/td>\n<\/tr>\n
16<\/td>\nScope
Summary of Test Method
Interferences
Apparatus
Reagents
Procedure <\/td>\n<\/tr>\n
17<\/td>\nCalculations
Reliability
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
Procedure <\/td>\n<\/tr>\n
18<\/td>\nCalculations
Reliability
Scope
Summary of Test Method <\/td>\n<\/tr>\n
19<\/td>\nInterferences
Apparatus
Reagents
Procedure
Precision and Bias
Scope
Summary of Test Method <\/td>\n<\/tr>\n
20<\/td>\nInterferences
Apparatus
Reagents
Procedure
Precision and Bias
Scope
Summary of Test Method
Apparatus
Reagents <\/td>\n<\/tr>\n
21<\/td>\nProcedure
Counting
Calculations <\/td>\n<\/tr>\n
22<\/td>\nPrecision and Bias
Sensitivity
Scope
Scope
Summary of Test Method
Interferences
Instrumentation and Apparatus
Reagents <\/td>\n<\/tr>\n
23<\/td>\nPreparation of Apparatus
Calibration
Procedure
Calculation
Precision and Bias
TABLE 5
TABLE 6 <\/td>\n<\/tr>\n
24<\/td>\nScope
Summary of Test Method
Interferences
Instrumentation and Apparatus
Reagents
TABLE 7
TABLE 8
TABLE 9 <\/td>\n<\/tr>\n
25<\/td>\nPreparation of Apparatus
Calibration and Standardization
Procedure
Calculation
Precision and Bias
TABLE 10 <\/td>\n<\/tr>\n
26<\/td>\nKeywords
REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

C761-11 Standard Test Methods for Chemical, Mass Spectrometric, Spectrochemical, Nuclear, and Radiochemical Analysis of Uranium Hexafluoride<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2011<\/td>\n26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":40292,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[464,2637],"product_tag":[],"class_list":{"0":"post-40291","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-27-120-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/40291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/40292"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=40291"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=40291"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=40291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}